archives

Introduction My CTP fellow James Rankin has written a very good article about the CVAD Clipboard Redidrection here , this article will share my findings and research about the clipboard redirection based on CVAD 1912 LTSR. Out-Of-Box Installation and the Security part If you install CVAD 1912 out of the box or updating it from […]

Continue Reading  

Introduction With Windows 10 1809 or 1909 I identify a bug with the Windows time zone in the Citrix HDX Session wiht HTML5 Receiver/Worksapce App only. On my local client the Windows time zone is well configured and Citrix uses the local time zone of the client. Workspace App for HTML5 Inside the Citrix Session […]

Continue Reading  

Introduction I’m happy to announce the new Release of the Cummunity Tool – Base Image Script Framework (BIS-F) Version 7.1912 (CodeName Bugs Bunny). On 8. November 2019 I’m release the public BETA at E2EVC in Lisbon and first I will say thank you very much for the great feedback in the last 7 weeks. During […]

Continue Reading  

From 08.-10 November 2019 the E2EVC is starting in Lisbon, this is one of the greatest events ever, Deep-Dive technical stuff only, no marketing bullshit. For those who ask, this was a great LED-Panel for the presentation.. looks like a poster I has presented the news of the BIS-F 7 1912 release.Please find below my […]

Continue Reading  

Introduction After an Image build is complete, it’s necessary to check the existing applications against the reference list, to see if something missed. Mostly you can implement this part in the ESD Solution, to check winword.exe, excel.exe, adoberdr.exe and all the other apps and executables that are required, are present on the image or you […]

Continue Reading  

Introduction After Upgrade of the existing StoreFront Group, the Users struggeling with the WebInterface (StoreWeb) and see a Spinning Weehl only, the Native Store was not affected. If you hit F5 for refresh the page loads and you can see your Applications. and Desktops, this happens for explicit and Domain Passtrough logons with different Browsers. […]

Continue Reading  

Introduction If you installing the Citrix VDA for Server or Workstation there is a TargetOSOptimizer included, this is the same as in the Citrix PVSTargetDevice Installer is included, but the path is different. VDA Optimization selection During the GUI Installer of the VDA you can select “Optimize Performance“… .. or with the Commadline for an […]

Continue Reading  

Introduction After switching from Windows 10 1703 to 1809 with same VDA 1811 and UPM as well, the Google Chrome Bookmarks are not synched back to the UPM ProfileStore. In Addition this happens on Windows Server 2019 too. All other files around in the Default Folder are synched back, what the hell… After some research, […]

Continue Reading  

8 Weeks ago, I’m installed a fresh new Site with 7.15 CU2, after updating the Citrix Site CU3, the monitoring system inform us about the following issue. With CU2 everything works well and the ServiceStatus shows “OK”. Rolling back the DB and the Controller now and open up a Citrix Case SR 78506137. If you […]

Continue Reading  

Since XenApp / XenDesktop 7.7 you can configure zones for geographic deployment around the globe, put your Delivery Controller in the Zones and so on, But Zone preferencing is more powerfull than that only. Remember to XenApp 6.5 you con configure prefered Loadbalancing to switch your users to other servers with the same published application […]

Continue Reading  

By continuing to use the site, you agree to the use of cookies. more information

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close